Adapters Connector Kits Patch Cords & Pigtails Pre - termination Fanout Cable Field Installable Connector FTTH terminal Boxes & Sockets Rack Mount Patch Panel ODF and Distribution Frame Optical Enclosure
Optical PLC Splitter Optical FBT Coupler CWDM Module 4CH/8CH CWDM Mux/Demux Module DWDM Module Optical Attenuator Optical Isolator Optical Circulator Optical Collimator Optical Reflector/Terminator Optical Loopback
S3900 Series is a new generation of aggregation 10G switches. It is targeted at the IP MAN (metropolitan areanetwork), campus networks and enterprise networks. It is developed on the basis of high performance hardware and software platform with own independent intellectual property rights. It supports multiple services like IPv6, VPN and network security based on L2/L3/L4 wire-speed switchingservice. It also supports non stop upgrade,- continuous forwarding, graceful restarting and redundancy protection.
S3900 Series has 5 models: S3900-24T6X, S3900-24S8T6X, S3900-48T6X, S3900-48M6X and S3900-48P6X.
It supports up to 48 gigabit ports and 6 10GE ports.
Innovative Virtual Cluster Switching Technique
BVSS system makes full use of each link in the physical devices, which avoids STP blocking the link and protects the original link to the maximum extent.
Improved Performance: virtualize multiple physical devices into one. The performance, reliability and management of the virtual system are superior to the physical ones.
High Reliability: Based on the advanced distribution mechanism and efficient cross-physical link aggrega- tion link function, the logic control plane, service control plane and service data plane are separated. Thus, the device can support continuous layer-3 routing forwarding, avoiding service interruption as a result of a single point of failure.
Easy Management: BVSS realizes single IP manage- ment, greatly improving the networking efficiency and lowering the operating cost.
Carrier-Level QoS Policies
Supports priority retagging and complicated flow classification based on VLAN, MAC, source address, destination address, IP or priority to better stream- line carrier’s services.Supports flexible bandwidth control policies and supports port-/flow-based flow limit, and ensuring the line speed forwarding of each port to make sure the high quality of video, audio and data services. Supports 8 priority queues by each port.Supports multiple queue schedule algorithms such as SP, WRR, and SP+WRR.
Varied Service Characteristics
Supports layer-2 and layer-3 multicast routing protocol, which enable the device can access to IPTV, HD video surveillance and HD video conference.Sup- ports layer-3 routing protocol and super-large routing table capacity, which enables the device is available in large campus networks, enterprise networks and industry networks.
Versatile IPv6 Solution
Supports the IPv6 protocol suite, IPv6 neighbor discovery, ICMPv6, path MTU discovery, DHCPv6, etc.Supports Ping, Traceroute, Telnet, SSH, ACL. Supports MLD, MLD Snooping, IPv6 static routing, RIPng, OSPFv3 and BGP4+, etc. Supports IPv6 tunnel: manual tunnel, automatic tunnel, GRE tunnel, 6to4, ISATAPSupports IPv4 transits to IPv6: IPv6 manual tunnel, automatic tunnel, 6 to 4 tunnel, ISATAP tunnel.
Industrial Ethernet Ring with Zero Delay and Zero Packet Loss
Supports industry-level EAPS and ERPS, and their protection recovery time is less than 50ms. Their high reliability is represented by the null packet loss, which has been proved by many years of application in the Grid, rail transportation and defense systems.
Intelligent PoE+
S3900-48P6X supports IEEE 802.3af/at PoE standard, and power mapping scales up to a maximum of 760W of PoE+ power;S3900-48P6X supports PoE non-stop power supply. The PoE+ power is main-tained during a switch reload; S3900-48P6X supports manual and dynamic PoE power allocation;
S3900-48P6X supports up to 6KV thunder-proof of the PoE port and power supply;
Complete Security Mechanism
Equipment-Level Security: The advanced hardware infrastructure design realizes the level-based packet schedule and packet protection, prevents DoS-/TCP- related SYN Flood, UDP Flood, Broadcast Storm or large traffic attacks, and supports level-based command line protection, endowing different levels of users with different management permissions.Se- curity Authentication Mechanism: IEEE 802.1x, Radius and Tacacs+Enhanced Service Security Mechanism: supports the plaintext or MD5 authenti- cation of relevant routing protocol, URPF, deep inspection of hardware packet, control packet and data packet and filtering technology.
Innovative Energy-Saving Design
Intelligent power management: The power system of S3900 series supports real-time monitoring the device and the slow-start. It is also power-saving.
Intelligent fan management system: The fan system of S3900 Series supports automatic speed regula- tion, which efficiently slow the fan speed and mitigate the noise. Complies with the international standard IEEE 802.3a
Flexible and Convenient Management and Maintenance
Supports management modes such as the console port, Telnet, SSH, etc.
Supports the WEB management mode, which is easy and efficient so that it makes installation and debugging convenient.Supports TFTP-patterned file upload/download management.
Supports ISSU (In-Service Software Upgrade). Supports SNMP and NMS smart network manage- ment platform to realize automatic equipment discovery, network topology management, equip- ment configuration management, performance data statistics and analysis and trouble management.
Product Specifications
Item | S3900-24T6X | S3900-24S8T6X | S3900-48T6X | S3900-48M6X | S3900-48P6X | |
GE Interface TX SFP | 24 / | 8 24 | 48 / | 24 24 | 48 / | |
10GE Interface | 6 10GE/GE | |||||
Console | 1 RJ45 Port | |||||
Backplane | 216 Gbps | |||||
Forwarding rate | 126 Mpps | 138 Mpps | 162 Mpps | 162 Mpps | 162 Mpps | |
Physical Specifications | ||||||
Chassis Dimensions (WxDxH) | 440x350x44 mm | |||||
Package Dimensions (WxDxH) | 576x448x94 mm | |||||
Power | ||||||
Power supply (AC: 100V-240V, 50Hz±10%) | 75 W | 75 W | 75 W | 75 W | ≤1000W (POE) | |
Total output BTU (1000BTU/H=293W) | 255.97 | 255.97 | 255.97 | 255.97 | 3412.96 | |
Noise@25°C(dBA) | 45 | |||||
MTBF(H) | >200,000 | |||||
Forwarding mode | Store-forward | |||||
Flash (MB) | 16 | |||||
DRAM (MB) | 512 | |||||
MAC | 32K | |||||
Buffer size(Mb) | 2 | |||||
Jumbo frame | 9K | |||||
Routing table | IPv4 | 12K | ||||
IPv6 | 6K | |||||
ARP table | IPv4 | 12K | ||||
IPv6 | 2K | |||||
Total SVI | 1K |
VLAN
• 4K Active VLAN,
• QinQ & Selective QinQ,
• GVRP,
• Voice-VLAN
Spanning Tree
• 802.1D (STP),
• 802.1W (RSTP) and 802.1S (MSTP) BPDU guard,
• root guard and loopback guard
Multicast
• PIM-SM, PIM-DM, IGMP v1/v2/v3,
• IGMP Snooping, IGMP Fast Leave,
• MVR, IGMP filter
IPv4
• Static routing, RIP v1/v2, OSPF, BGP, PBR, ECMP
• BFD for OSPF, BGP
DHCP
• DHCP server/relay/client
• DHCP snooping/option82
MPLS
• Multi-VRF
Certification
CE, FCC, ROHS
IPv6
• ICMPv6, DHCPv6, ACLv6 and IPv6 Telnet
• IPv6 neighbor discovery, Path MTU discovery
• MLD V1/V2, MLD snooping
• IPv6 Static Routing, RIPng, OSPFv3, BGP4+
• Manual tunnel, ISATAP tunnel, 6 to 4 tunnel
QoS
• CAR, HQoS, MAC/IP/TCP/UD- P/VLAN/COS/DSCP/TOS based QoS, 802.1P/DSCP priority re-labeling, SP, WRR, and“SP+WRR”, Tail-Drop, WRED, flow monitoring and traffic shaping
Security
• Port isolation, Port security, and “IP+MAC+port” binding, MAC sticky, DAI & IP source guard, PPPoE+
• IEEE 802.1x, Radius and Tacacs+
• L2/L3/L4 ACL flow identifica- tion and filtration Anti-attack from DDoS, TCP’s SYN Flood, UDP Flood, etc.
Reliability
• Static/LACP link aggregation, Interface backup
• BVSS virtual-stacking
• EAPS and ERPS
• URPF, LLDP
• ISSU
• VRRP
• 1+1 power backup
Management
• Console, Telnet, SSH v1/2, HTTP, HTTPS
• SNMP v1/v2/v3, RMON
• TFTP, FTP, SFTP
• NTP, SPAN, RSPAN
• sFlow
Environment
• Operating temperature/ humidity: 0ºC -50ºC, 10%-90% non-condensing
• Storage temperature/humidity: -20ºC -70ºC, 5%-95% non-condensing Accessories
• Power cord, rackmount kits, console cable
Ordering Information
Item | Description |
S3900-24T6X | Ethernet routing switch with 24 GE and 6 10GE ports (1 RJ45 console port, 24 GE TX ports, 6 10GE/GE SFP+ ports; 2 power slots with 1 hot-swap AC220V power supply; the cooling fan, 1U, standard 19-inch rack-mounted installation) |
S3900-24S8T6X | Ethernet routing switch with 32 GE and 6 10GE ports (1 RJ45 console port, 24 100M/ 1000M SFP ports, 8 GE TX ports, 6 10GE/GE SFP+ ports; 2 power slots with 1 hot-swap AC220V power supply; the cooling fan, 1U, standard 19-inch rack-mounted installation) |
S3900-48T6X | Ethernet routing switch with 48 GE and 6 10GE ports (1 RJ45 console port, 48 GE TX ports, 6 10GE/GE SFP+ ports; 2 power slots with 1 hot-swap AC220V power supply; the cooling fan, 1U, standard 19-inch rack-mounted installation) |
S3900-48M6X | Ethernet routing switch with 48 GE and 6 10GE ports (1 RJ45 console port, 24 GE TX ports, 24 100M/1000M SFP ports, 6 10GE/GE SFP+ ports; 2 power slots with 1 hot-swap AC220V power supply; the cooling fan, 1U, standard 19-inch rack-mounted installation) |
S3900-48P6X | Ethernet routing switch with 48 GE POE and 6 10GE ports (1 RJ45 console port, 48 GE POE TX ports, 6 10GE/GE SFP+ ports; 2 power slots with 1 hot-swap AC220V power supply; thecooling fan, 1U, standard 19-inch rack-mounted installation) |
S3900 Series Non-POE Power Modules | |
PWR-75-AC | Hot-swap AC Power for S3900 Series (75W max, AC100~240V input) |
PWR-75-DC | Hot-swap DC Power for S3900 Series (75W max, DC-36~-72V input) |
S3900 Series POE Power Modules | |
POE-500-AC | Hot-swap power supply of S3900 POE switch series (500W max power, 380W max POE power, AC100~240V input, the isolated cooling fan) |
10GE optical modules | |
SFP+TX | 10GE SFP+-to-RJ45 module |
SFP+SX | 10GE SFP+ multi-mode (300m, 850nm, LC) |
SFP+LX-10 | 10GE SFP+ single-mode (10Km, 1310nm, LC, DDM) |
SFP+LX-20 | 10GE SFP+ single-m ode (20Km, 1310nm, LC, DDM) |
SFP+LX-40 | 10GE SFP+ single-mode (40Km, 1310nm, LC, DDM) |
SFP+LX-80 | 10GE SFP+ single-m ode (80Km, 1550nm, LC, DDM) |
SFP+LX-SM-1270-10 | 10GE SFP+ single-mode, single-fiber (10Km, TX1270/RX1330, LC, DDM) |
SFP+LX-SM-1330-10 | 10GE SFP+ single-mode, single-fiber (10Km,TX1330/RX1270, LC, DDM) |
SFP+LX-SM-1270-20 | 10GE SFP+ single-mode, single-fiber (20Km, TX1270/RX1330, LC, DDM) |
SFP+LX-SM-1330-20 | 10GE SFP+ single-mode, single-fiber (20Km,TX1330/RX1270, LC, DDM) |
SFP+LX-SM-1270-40 | 10GE SFP+ single-mode, single-fiber (40Km, TX1270/RX1330, LC, DDM) |
SFP+LX-SM-1330-40 | 10GE SFP+ single-mode, single-fiber (40Km,TX1330/RX1270, LC, DDM) |
GE Optical Modules | |
GSFP-TX-B | GE SFP-to-RJ45 module |
GSFP-SX-D | GE SFP multi-mode (500m, 850nm, LC, DDM) |
GSFP-LX-10-D | GE SFP single-mode (10Km, 1310nm, LC, DDM) |
GSFP-LX-20-D | GE SFP single-mode (40Km, 1310nm, LC, DDM) |
GSFP-LX-40-D | GE SFP single-mode (40Km, 1310nm, LC, DDM) |
GSFP-ZX-80-D | GE SFP single-m ode (80Km, 1550nm, LC, DDM) |
GSFP-ZX-120-D | GE SFP single-m ode (120Km, 1550nm, LC, DDM) |
GSFP-LX-SM1310-10-BIDI | GE SFP single-mode, single fiber (10Km, TX1310/RX1550, LC, DDM) |
GSFP-LX-SM1550-10-BIDI | GE SFP single-mode, single fiber (10Km, TX1550/RX1310, LC, DDM) |
GSFP-LX-SM1310-20-BIDI | GE SFP single-mode, single fiber (20Km, TX1310/RX1550, LC, DDM) |
GSFP-LX-SM1550-20-BIDI | GE SFP single-mode, single fiber (20Km, TX1550/RX1310, LC, DDM) |