Adapters Connector Kits Patch Cords & Pigtails Pre - termination Fanout Cable Field Installable Connector FTTH terminal Boxes & Sockets Rack Mount Patch Panel ODF and Distribution Frame Optical Enclosure
Optical PLC Splitter Optical FBT Coupler CWDM Module 4CH/8CH CWDM Mux/Demux Module DWDM Module Optical Attenuator Optical Isolator Optical Circulator Optical Collimator Optical Reflector/Terminator Optical Loopback
S2500-C Series is a new-generation intelligent gigabit access switch designed for carrier's IP MAN and enterprise networks. Based on the new-generation high-performance hardware and BDROS platform,it supports functions such as ACL, QinQ andQoS. Its simple management mode andflexible installation can meet the requirement of any complicated scenarios.
S2500-C Series has 2 models: S2510-C & S2528-C.
Carrier-Level Ethernet Access Switch
S2500-C Series supports the carrier-level Ethernet-ring protection protocol with less than 50ms recovery time, STP/RSTP/MSTP, backup uplink ports,and LACP link aggregation to cater to the requirements of high reliability of carriers;
S2500-C Series has powerful ACL functions to access and control L2-L7 data based on physical port, providing carriers flexible and various policy
control methods;
S2500-C Series supports In-Service Software Upgrade (ISSU) to ensure the unremitting data forwarding during system upgrade;
S2500-C Series supports various L2 multicast functions such as IGMP-snooping, fast-leave and MVR to fully meet the operation requirements of carrier’s IPTV.
Comprehensive IPv6 Solutions
S2500-C Series supports the IPv6 protocol suite, IPv6 neighbor discovery, ICMPv6 and Path MTU discovery.
S2500-C Series supports Ping, Traceroute, Telnet, SSH and ACL on the basis of IPv6, meeting IPv6 networks' equipment management requirements and service control requirements;
Enhanced QoS
S2500-C Series supports priority retagging and complicated flow classification based on VLAN, MAC, source address, destination address, IP or priority, better streamlining carrier’s services.
S2500-C Series provides flexible bandwidth control policies, supporting port-/flow-based flow limit, ensuring the line speed forwarding of each port.
S2500-C Series supports multiple queue schedule algorithms such as SP, WRR and “SP + WRR”.
Security+
Equipment-level security: The advanced hardware infrastructure design realizes the level-based packet schedule and packet protection, prevents DoS-/TCP- related SYN Flood, UDP Flood, Broadcast Storm or large traffic attacks, and supports level-based command line protection, endowing different levels of users with different management permissions.
Perfect security authentication mechanisms: IEEE 802.1x, Radius and BDTacacs+.
S2500-C Series supports storm/multicast/unicast limit, ensuring the normal running of equipment in harsh network conditions.
S2500-C Series supports perfect ring detection mechanism, ensuring the long-term stable running of network.
S2500-C Series supports port isolation within the same VLAN, DHCP-Snooping, and IP + MAC + Port binding.
Easy Management and Maintenance
S2500-C Series supports many management modes such as the CLI, Telnet, SSH, SSL and SNMP.
S2500-C Series supports the WEB management mode, which is easy and efficient for installing and debugging the device.
S2500-C Series supports FTP,TFTP and SFTP.
S2500-C Series supports ISSU (In-Service Software Upgrade).
S2500-C Series supports SNMP and BDCOM NMS smart network management platform. The combination realizes automatic equipment discovery, network topology management, equpment configuration management, performance data statistics and analysis and trouble management.
S2500-C Series supports Zero Touch Provisioning(ZTP) function to minimize manual operator intervention and helps reduce customers’ initial deployment costs.
Product Specifications
Item | S2510-C | S2528-C | ||
Interface | 8 GE TX ports, 2 100/1000M SFP ports | 24 GE TX ports, 4 100/1000M SFP ports | ||
Console | 1 RJ45 port, 1 RST button | 1 RJ45 port, 1 RST button | ||
Backplane | 20 Gbps | 56 Gbps | ||
Forwarding rate | 15 Mpps | 42 Mpps | ||
Chassis | Dimensions (WxDxH) | 280x180x44 mm | 440x210x44 mm | |
Weight (empty) | 1.55 KG | 2 KG | ||
Package | Dimensions (WxDxH) | 346x289x92 mm | 555x295x88 mm | |
Weight | 2.55 KG | 3 KG | ||
Power consumption | no-load | <3 W | <7 W | |
full-load | 10 W | 20 W | ||
Power supply (AC: 100V-240V, 50Hz±10%) | 15 W | 25 W | ||
Total output BTU (1000BTU/H=293W) | 51.19 | 85.32 | ||
Fan number | no | |||
Noise@25°C(dBA) | 0 | |||
MTBF(H) | >50,000 | |||
Forwarding mode | Store-forward | |||
Flash (MB) | 16 | |||
DRAM (MB) | 128 | |||
MAC | 8K | |||
Buffer size(Mb) | 4.1 | |||
Jumbo frame | 9K | |||
Total SVI | 10 |
VLAN
• 4K Active VLAN
• QinQ & Selective QinQ
• GVRP, Private VLAN
• Voice VLAN
Spanning Tree
• 802.1D (STP)
• 802.1W (RSTP) and 802.1S (MSTP)
• BPDU guard, root guard and loopback guard
Multicast
• IGMP v1/2/3
• IGMP Snooping
• IGMP Fast Leave
• IGMP Filter
• MVR
IP
• Static route
• RIP, OSPF
• 512 routing table
• IP v4/v6 dual stack
• DHCP Server/Client/Relay
QoS
• CAR, HQoS, MAC/IP/TCP/UDP/VLAN/COS/DSCP/TOS based
• QoS,802.1P/DSCP priority relabeling, SP, WRR, and“SP+WRR”,
• Tail-Drop, WRED, flow monitoring and traffic shaping.
Security
• Port isolation, Port security, and“IP+MAC+port” binding, MAC sticky, DHCP Snooping and option 82, DAI & IP source guard, PPPoE+, IEEE 802 .1x , Radius and Tacacs+L2/L3/L4 ACL flow identification and filtration Anti-attack from. DDoS, TCP’s SYN Flood, UDP Flood, etc.
• Broadcast/multicast/unknown unicast storm-control
• MD5, SHA-256, RSA-1024, AES256, etc.
Reliability
• Static/LACP link aggregation, Interface backup EAPS and ERPS
• ISSU
Management
• Console, Telnet , SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON
• TFTP, FTP, SFTP
• NTP
• ZTP(Zero Touch Provisioning) SPAN, RSPAN
Accessories
• Power cord, rackmount kits, console cable, anti-slipping pad Environment
• Operating temperature/humidity: 0ºC -50ºC, 10%-90% non-condensing
• Storage temperature/humidity: -20ºC -70ºC, 5%-95% noncondensing
Certification
CE, FCC, ROHS
Ordering Information
Item | Description |
S2510-C | Ethernet switch with 8 GE TX ports and 2 GE SFP ports (1 console port, 8 GE TX ports, 2 100/1000M SFP ports, 1 standard AC220V power supply, fanless, 1U, desktop installation) |
S2528-C | Ethernet switch with 24 GE TX ports and 4 GE SFP ports (1 console port, 24 GE TX ports, 4 100/1000M SFP ports, 1 standard AC220V power supply, fanless, 1U, 19-inch rack-mounted installation) |
100M Optical Modules | |
FSFP-SX-1310 | 100M SFP multi-mode (2Km, 1310nm, LC, DDM) |
FSFP-LX-15 | 100M SFP single-mode (15Km, 1310nm, LC, DDM) |
FSFP-LX-40 | 100M SFP single-mode (40Km, 1310nm, LC, DDM) |
FSFP-ZX-80 | 100M SFP single-mode (80Km, 1550nm, LC, DDM) |
FSFP-LX-SM1310-20-BIDI FSFP-LX-SM1550-20-BIDI | 100M SFP single-mode, single fiber (20Km, TX1310/RX1550, LC, DDM) 100M SFP single-mode, single fiber (20Km, TX1550/RX1310, LC, DDM) |
FSFP-LX-SM1310-40-BIDI FSFP-LX-SM1550-40-BIDI | 100M SFP single-mode, single fiber (40Km, TX1310/RX1550, LC, DDM) 100M SFP single-mode, single fiber (40Km, TX1550/RX1310, LC, DDM) |
FSFP-LX-SM1310-80-BIDI FSFP-LX-SM1550-80-BIDI | 100M SFP single-mode, single fiber (80Km, TX1310/RX1550, LC, DDM) 100M SFP single-mode, single fiber (80Km, TX1550/RX1310, LC, DDM) |
GE Optical Modules | |
GSFP-TX-B | GE SFP-to-RJ45 module |
GSFP-SX-D | GE SFP multi-mode(500m,850nm,LC,DDM) |
GSFP-LX-10-D | GE SFP single-mode(10Km,1310nm,LC,DDM) |
GSFP-LX-20-D | GE SFP single-mode (40Km, 1310nm, LC, DDM |
GSFP-LX-40-D | GE SFP single-mode (40Km, 1310nm, LC, DDM) |
GSFP-ZX-80-D | GE SFP single-mode (80Km, 1550nm, LC, DDM) |
GSFP-ZX-120-D | GE SFP single-mode (120Km, 1550nm, LC, DDM) |
GSFP-LX-SM1310-10-BIDI GSFP-LX-SM1550-10-BIDI | GE SFP single-mode, single fiber (10Km, TX1310/RX1550, LC, DDM) GE SFP single-mode, single fiber (10Km, TX1550/RX1310, LC, DDM) |
GSFP-LX-SM1310-20-BIDI GSFP-LX-SM1550-20-BIDI | GE SFP single-mode, single fiber (20Km, TX1310/RX1550, LC, DDM) GE SFP single-mode, single fiber (20Km, TX1550/RX1310, LC, DDM) |
GSFP-LX-SM1310-40-BIDI GSFP-LX-SM1550-40-BIDI | GE SFP single-mode, single fiber (40Km, TX1310/RX1550, LC, DDM) GE SFP single-mode, single fiber (40Km, TX1550/RX1310, LC, DDM) |
GSFP-LX-SM1490-80-BIDI GSFP-LX-SM1550-80-BIDI | GE SFP single-mode, single fiber (80Km, TX1490/RX1550, LC, DDM) GE SFP single-mode, single fiber (80Km, TX1550/RX1490, LC, DDM) |
GSFP-LX-SM1490-120 GSFP-LX-SM1550-120 | GE SFP single-mode, single fiber (120Km, TX1490/RX1550, LC, DDM) GE SFP single-mode, single fiber (120Km, TX1550/RX1490, LC, DDM) |